Omnia Plus On/ Off Heat Pump R22

  • Optimal conditions thanks to Anti-Cold Air Function
  • 24-Hours Timer for more convenience and energy savings
  • Sleep mode for perfect sleeping conditions

Become an Inventor Partner

  • MODEL O1HMI - 09 / O1HMO - 09
  • Cooling Capacity 9.000 Btu / h
  • Cooling Capacity 2.64 kWatt
  • Heating Capacity 9.500 Btu / h
  • Heating Capacity 2.78 kWatt
  • EER 2.61 W / W
  • COP 2.81 W / W
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 4.4 A
  • Current Input-Heating 4.3
  • Power Input-Cooling 1.010 W
  • Power Input-Heating 990
  • Air Flow Volume (Hi / Med / Low) 457 / 405 / 351 m³ / h
  • Noise Level-Indoor Unit 30.6 / 35.7 / 39.6 (db(A))
  • Noise Level-Outdoor Unit 54.9
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4" / 3/8"
  • Dimensions -Indoor Unit WxDxH 715 × 194 × 285 mm
  • Dimensions - Outdoor Unit WxDxH 681 × 285 × 434
  • Net Weight Indoor / Outdoor 7.6 / 23.5 kg
  • Refrigerant R22 / 550g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24
  • Loading Quantities per 20’ / 40’HC 140 / 320
  • MODEL O1HMI - 12 / O1HMO - 12
  • Cooling Capacity 12.000 Btu / h
  • Cooling Capacity 3.52 kWatt
  • Heating Capacity 13.000 Btu / h
  • Heating Capacity 3.81 kWatt
  • EER 2.61 W / W
  • COP 3.26 W / W
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 5.8 A
  • Current Input-Heating 5.1
  • Power Input-Cooling 1.347 W
  • Power Input-Heating 1.168
  • Air Flow Volume (Hi / Med / Low) 574 / 447 / 350 m³ / h
  • Noise Level-Indoor Unit 32.2 / 37.8 /42.9 (db(A))
  • Noise Level-Outdoor Unit 55.1
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4" / 1/2"
  • Dimensions -Indoor Unit WxDxH 805 × 194 × 285 mm
  • Dimensions - Outdoor Unit WxDxH 770 × 300 × 555
  • Net Weight Indoor / Outdoor 8.5 / 28.9 kg
  • Refrigerant R22 / 880g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24
  • Loading Quantities per 20’ / 40’HC 104 / 240
  • MODEL O1HMI - 18 / O1HMO - 18
  • Cooling Capacity 17.000 Btu / h
  • Cooling Capacity 4.98 kWatt
  • Heating Capacity 18.000 Btu / h
  • Heating Capacity 5.28 kWatt
  • EER 2.61 W / W
  • COP 3.01 W / W
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 8.3 A
  • Current Input-Heating 7.6
  • Power Input-Cooling 1.908 W
  • Power Input-Heating 1.752
  • Air Flow Volume (Hi / Med / Low) 751 / 607 / 488 m³ / h
  • Noise Level-Indoor Unit 33.8 / 38.8 / 43.9 (db(A))
  • Noise Level-Outdoor Unit 58.2
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4" / 1/2"
  • Dimensions -Indoor Unit WxDxH 957 × 213 × 302 mm
  • Dimensions - Outdoor Unit WxDxH 770 × 300 × 555
  • Net Weight Indoor / Outdoor 10.6 / 35.7 kg
  • Refrigerant R22 / 1.250g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24
  • Loading Quantities per 20’ / 40’HC 90 / 208
  • MODEL O1HMI - 24 / O1HMO - 24
  • Cooling Capacity 22.000 Btu / h
  • Cooling Capacity 6.45 kWatt
  • Heating Capacity 23.000 Btu / h
  • Heating Capacity 6.74 kWatt
  • EER 2.61 W / W
  • COP 3.01 W / W
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 10.7 A
  • Current Input-Heating 9.7
  • Power Input-Cooling 2.470 W
  • Power Input-Heating 2.238
  • Air Flow Volume (Hi / Med / Low) 1.066 / 956 / 764 m³ / h
  • Noise Level-Indoor Unit 38.8 / 43.9 / 46.4 (db(A))
  • Noise Level-Outdoor Unit 58.8
  • Compressor Type ROTARY
  • Liquid line / Gas line 3 / 8" / 5/8"
  • Dimensions -Indoor Unit WxDxH 1.040×220×327 mm
  • Dimensions - Outdoor Unit WxDxH 845 × 363 × 702
  • Net Weight Indoor / Outdoor 13.4 / 47.9 kg
  • Refrigerant R22 / 1.700g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24
  • Loading Quantities per 20’ / 40’HC 66 / 154

Diese Funktion erhöht die Kühl- und Heizleistung für einen bestimmten Zeitraum und lässt den Raum schnell abkühlen oder schnell aufwärmen.

Turbo Modus

Programmieren Sie die Einheit so , dass sie innerhalb von 24 Stunden Periode automatisch auf EIN und AUS eingestellt werden kann .

24-Stunden-Timer

Sobald ein abnormaler Betrieb oder ein Teileausfall auftritt, schaltet sich die Einheit automatisch aus, um das System zu schützen. In der Zwischenzeit wird eine Schutz oder Fehleranzeige für eine schnelle Wartung angezeigt.

Automatische Fehlerdiagnose

Wenn die Klimaanlage aufgrund eines Stromausfalls unerwartet ausfällt, wird sie automatisch mit dem vorherigen Einstellungen wieder aktiviert , sobald die Stromversorgung wieder aufgenommen wird.

Automatischer Neustart

Nach dem Einstellen der gewünschten Temperatur passt das Gerät seinen Betrieb automatisch an, um die von Ihnen eingestellte Temperatur auszugleichen.

Die horizontale Jalousie platziert sich beim Einschalten des Gerätes automatisch in die selbe Position, in der sie letztes Mal eingestellt wurde.

Das Innengerät zeigt den Fehlercode „EC“ an und stoppt automatisch, wenn ein Kältemittellverlust festgestellt wird.

Da die horizontale Klappen automatisch bewegt werden, wird die kühle / warme Luft in einer maximalen Fläche im Raum verteilt.

Sowohl die linke als auch die rechte Seite des Innengerätes ermöglichen den Anschluss des Abflussschlauchs , was die Installation erleichtert.  

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …