Core On / Off Heat Pump R410A

  • A Energy Class for a higher and more efficient performance
  • Blow Xfan to eliminate unwanted moisture in indoor unit
  • Achieve power saving and improved heating efficiency thanks to Intelligent Defrost

Become an Inventor Partner

  • MODEL APSI - 09 / APSO - 09
  • 9,000
  • Cooling Capacity 2.64 kWatt
  • 9,600
  • Heating Capacity 2.81 kWatt
  • EER 3.22 W / W
  • COP 3.61 W / W
  • Energy Class A / A
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 4.60 A
  • Current Input-Heating 5.10 A
  • Power Input-Cooling 821 W
  • Power Input-Heating 779 W
  • Air Flow Volume (Hi / Med / Low) 400 m³ / h
  • Noise Level-Indoor Unit 37 (db(A))
  • Noise Level-Outdoor Unit 50 (db(A))
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4” / 3 / 8”
  • Dimensions -Indoor Unit WxDxH 730 × 255 × 174 mm
  • Dimensions - Outdoor Unit WxDxH 785 × 540 × 320 mm
  • Net Weight Indoor / Outdoor 8 / 31 kg
  • Refrigerant R410A / 760g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24 ͦC
  • Loading Quantities per 20’ / 40’HC 116 / 280
  • MODEL A1PSI - 12 / A1PSO - 12
  • 11,000
  • Cooling Capacity 3.22 kWatt
  • 11,997
  • Heating Capacity 3.52 kWatt
  • EER 3.21 W / W
  • COP 3.62 W / W
  • Energy Class A / A
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 6.30 A
  • Current Input-Heating 6.10 A
  • Power Input-Cooling 1,004 W
  • Power Input-Heating 973 W
  • Air Flow Volume (Hi / Med / Low) 550 m³ / h
  • Noise Level-Indoor Unit 38 (db(A))
  • Noise Level-Outdoor Unit 52 (db(A))
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4” / 1 / 2”
  • Dimensions -Indoor Unit WxDxH 790 × 265 × 177 mm
  • Dimensions - Outdoor Unit WxDxH 798 × 540 × 320 mm
  • Net Weight Indoor / Outdoor 9 / 35 kg
  • Refrigerant R410A / 840g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24 ͦC
  • Loading Quantities per 20’ / 40’HC 110 / 269
  • MODEL APSI - 18 / APSO - 18
  • 16,036
  • Cooling Capacity 4.70 kWatt
  • 16,720
  • Heating Capacity 4.90 kWatt
  • EER 3.22 W / W
  • COP 3.43 W / W
  • Energy Class A / B
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 10.00 A
  • Current Input-Heating 10.00 A
  • Power Input-Cooling 1,460 W
  • Power Input-Heating 1,430 W
  • Air Flow Volume (Hi / Med / Low) 850 m³ / h
  • Noise Level-Indoor Unit 45 (db(A))
  • Noise Level-Outdoor Unit 55 (db(A))
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4” / 1 / 2”
  • Dimensions -Indoor Unit WxDxH 940 × 298 × 200 mm
  • Dimensions - Outdoor Unit WxDxH 848 × 540 × 320 mm
  • Net Weight Indoor / Outdoor 10 / 40 kg
  • Refrigerant R410A / 1.150g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24 ͦC
  • Loading Quantities per 20’ / 40’HC 87 / 210
  • MODEL A1PSI - 24 / A1PSO - 24
  • 21,000
  • Cooling Capacity 6.15 kWatt
  • 22,178
  • Heating Capacity 6.50 kWatt
  • EER 3.24 W / W
  • COP 3.42 W / W
  • Energy Class A / A
  • Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling 11.30 A
  • Current Input-Heating 11.70 A
  • Power Input-Cooling 1,900 W
  • Power Input-Heating 1,900 W
  • Air Flow Volume (Hi / Med / Low) 850 m³ / h
  • Noise Level-Indoor Unit 44 (db(A))
  • Noise Level-Outdoor Unit 56 (db(A))
  • Compressor Type ROTARY
  • Liquid line / Gas line 1 / 4” / 1 / 2”
  • Dimensions -Indoor Unit WxDxH 940 × 298 × 200 mm
  • Dimensions - Outdoor Unit WxDxH 913 × 680 × 378 mm
  • Net Weight Indoor / Outdoor 13 / 46 kg
  • Refrigerant R410A / 1.450g
  • Operation Temperature Range-Cooling 18~43 ͦC
  • Operation Temperature Range-Heating -7~24 ͦC
  • Loading Quantities per 20’ / 40’HC 64 / 154

Diese Funktion erhöht die Kühl- und Heizleistung für einen bestimmten Zeitraum und lässt den Raum schnell abkühlen oder schnell aufwärmen.

Turbo Modus

Programmieren Sie die Einheit so , dass sie innerhalb von 24 Stunden Periode automatisch auf EIN und AUS eingestellt werden kann .

24-Stunden-Timer

Sobald ein abnormaler Betrieb oder ein Teileausfall auftritt, schaltet sich die Einheit automatisch aus, um das System zu schützen. In der Zwischenzeit wird eine Schutz oder Fehleranzeige für eine schnelle Wartung angezeigt.

Automatische Fehlerdiagnose

Wenn die Klimaanlage aufgrund eines Stromausfalls unerwartet ausfällt, wird sie automatisch mit dem vorherigen Einstellungen wieder aktiviert , sobald die Stromversorgung wieder aufgenommen wird.

Automatischer Neustart

Nach dem Einstellen der gewünschten Temperatur passt das Gerät seinen Betrieb automatisch an, um die von Ihnen eingestellte Temperatur auszugleichen.

Da die horizontale Klappen automatisch bewegt werden, wird die kühle / warme Luft in einer maximalen Fläche im Raum verteilt.

Sowohl die linke als auch die rechte Seite des Innengerätes ermöglichen den Anschluss des Abflussschlauchs , was die Installation erleichtert.  

Die Drehzahlen des Innenventilators werden automatisch von der niedrigsten bis zur eingestellten Stufe entsprechend der Verdampfungsertemperatur geregelt, sobald das Gerät den Heizbetrieb aufnimmt.

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …