Features
Become an Inventor Partner
Specs
- MODEL RHSI - 09 / RHSO - 09
- 9,000
- Cooling Capacity 2.64 kWatt
- 9,600
- Heating Capacity 2.81 kWatt
- EER 2.61 W / W
- COP 2.61 W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 6.60 A
- Current Input-Heating 6.20 A
- Power Input-Cooling 1,010 W
- Power Input-Heating 1,078 W
- Air Flow Volume (Hi / Med / Low) 400 m³ / h
- Noise Level-Indoor Unit 37 (db(A))
- Noise Level-Outdoor Unit 50 (db(A))
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4” / 3 / 8”
- Dimensions -Indoor Unit WxDxH 730 × 255 × 174 mm
- Dimensions - Outdoor Unit WxDxH 720 × 430 × 310 mm
- Net Weight Indoor / Outdoor 8 / 27 kg
- Refrigerant R22 / 590g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -7~24 ͦC
- Loading Quantities per 20’ / 40’HC 150 / 350
- MODEL RHSI - 12 / RHSO - 12
- 11,000
- Cooling Capacity 3.22 kWatt
- 11,500
- Heating Capacity 3.37 kWatt
- EER 2.61 W / W
- COP 2.89 W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 6.30 A
- Current Input-Heating 6.30 A
- Power Input-Cooling 1,235 W
- Power Input-Heating 1,165 W
- Air Flow Volume (Hi / Med / Low) 550 m³ / h
- Noise Level-Indoor Unit 38 (db(A))
- Noise Level-Outdoor Unit 52 (db(A))
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4” / 1 / 2”
- Dimensions -Indoor Unit WxDxH 790 × 265 × 177 mm
- Dimensions - Outdoor Unit WxDxH 772 × 540 × 320 mm
- Net Weight Indoor / Outdoor 9 / 32 kg
- Refrigerant R22 / 870g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -7~24 ͦC
- Loading Quantities per 20’ / 40’HC 110 / 269
- MODEL RHSI - 18 / RHSO - 18
- 15,354
- Cooling Capacity 4.50 kWatt
- 16,378
- Heating Capacity 4.8 kWatt
- EER 2.50 W / W
- COP 2.67 W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 12.10 A
- Current Input-Heating 10.30 A
- Power Input-Cooling 1,800 W
- Power Input-Heating 1,800 W
- Air Flow Volume (Hi / Med / Low) 650 m³ / h
- Noise Level-Indoor Unit 43 (db(A))
- Noise Level-Outdoor Unit 57 (db(A))
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4” / 1 / 2”
- Dimensions -Indoor Unit WxDxH 845 × 275 × 186 mm
- Dimensions - Outdoor Unit WxDxH 848 × 540 × 320 mm
- Net Weight Indoor / Outdoor 10 / 42 kg
- Refrigerant R22 / 1.040g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -7~24 ͦC
- Loading Quantities per 20’ / 40’HC 101 / 244
- MODEL RHSI - 24 / RHSO - 24
- 21,000
- Cooling Capacity 6.16 kWatt
- 22,860
- Heating Capacity 6.7 kWatt
- EER 2.74 W / W
- COP 2.98 W / W
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input-Cooling 13.70 A
- Current Input-Heating 12.95 A
- Power Input-Cooling 2,250 W
- Power Input-Heating 2,250 W
- Air Flow Volume (Hi / Med / Low) 850 m³ / h
- Noise Level-Indoor Unit 45 (db(A))
- Noise Level-Outdoor Unit 57 (db(A))
- Compressor Type ROTARY
- Liquid line / Gas line 1 / 4” / 1 / 2”
- Dimensions -Indoor Unit WxDxH 940 × 298 × 200 mm
- Dimensions - Outdoor Unit WxDxH 955 × 700 × 424 mm
- Net Weight Indoor / Outdoor 13 / 56 kg
- Refrigerant R22 / 1.510g
- Operation Temperature Range-Cooling 18~43 ͦC
- Operation Temperature Range-Heating -7~24 ͦC
- Loading Quantities per 20’ / 40’HC 60 / 149
Benefits
Turbo Modus
Diese Funktion erhöht die Kühl- und Heizleistung für einen bestimmten Zeitraum und lässt den Raum schnell abkühlen oder schnell aufwärmen.

24-Stunden-Timer
Programmieren Sie die Einheit so , dass sie innerhalb von 24 Stunden Periode automatisch auf EIN und AUS eingestellt werden kann .

Automatischer Neustart
Wenn die Klimaanlage aufgrund eines Stromausfalls unerwartet ausfällt, wird sie automatisch mit dem vorherigen Einstellungen wieder aktiviert , sobald die Stromversorgung wieder aufgenommen wird.

Automatische Fehlerdiagnose
Sobald ein abnormaler Betrieb oder ein Teileausfall auftritt, schaltet sich die Einheit automatisch aus, um das System zu schützen. In der Zwischenzeit wird eine Schutz oder Fehleranzeige für eine schnelle Wartung angezeigt.

More
Automatische Lamelensteuerung
Da die horizontale Klappen automatisch bewegt werden, wird die kühle / warme Luft in einer maximalen Fläche im Raum verteilt.
Automatischer Betrieb
Nach dem Einstellen der gewünschten Temperatur passt das Gerät seinen Betrieb automatisch an, um die von Ihnen eingestellte Temperatur auszugleichen.
Lamellenpositionsspeicher
Die horizontale Jalousie platziert sich beim Einschalten des Gerätes automatisch in die selbe Position, in der sie letztes Mal eingestellt wurde.
Zwei-Wege-Entleerung
Sowohl die linke als auch die rechte Seite des Innengerätes ermöglichen den Anschluss des Abflussschlauchs , was die Installation erleichtert.
All you need to know about
Register now using your e-mail and get all the latest news in the world of air conditioning and more …