Features
Become an Inventor Partner
Technical Specifications
- V4MFI - 24 / V4MF0 - 24
- Cooling Capacity 24.000 Btu / h
- Heating Capacity 26.000 Btu / h
- Cooling Capacity Range (7.500 - 26.500) Btu / h
- Cooling Capacity Range 7.03 (2.19 - 7.77) kWatt
- Heating Capacity (5.200 - 29.500) Btu / h
- Heating Capacity 7.62 (1.52 - 8.65) kWatt
-
Seasonal Efficiency(In accordance
to EN14825) Cooling - Pdesign 7.0 kW
- Energy Class Α++
- SEER 6.1
-
Seasonal Efficiency(In accordance
to EN14825) Heating Middle Zone - Pdesign 5.8 kW
- Energy Class Α+
- SCOP 4.0
-
Seasonal Efficiency(In accordance
to EN14825) Heating Warm Zone - Pdesign 5.5 kW
- Energy Class A+++
- SCOP 5.1
- EER / COP -
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 10.19 Α
- Current Input - Heating 9.2 Α
- Power Input - Cooling 2.345 W
- Power Input - Heating 2.117 W
- Air Flow Volume (High/Medium/Low) 1.230 / 1.080 / 978 m3 / h
- Noise Level - Indoor unit (Low/Medium/High) 43.5 / 46 / 49.5 dB (A)
- Noise Level - Outdoor unit 60.5 dB (A)
- Sound Power Level - Indoor/Outdoor unit 63 / 65 dB (A)
- Power Supply Wire Outdoor / Fuses 3 × 2.5 / 1 × 20 No x mm2 / Α
- Signal Wires 3 × 1.5 & (4 × 1.0 Shield) No x mm2
- Dimensions WxDxH - Indoor unit 500 × 315 × 1.700 mm
- Dimensions WxDxH - Outdoor unit 845 × 363 × 702 mm
- Net Weight - Indoor / Outdoor 37.5 / 49 kg
- Liquid line | Gas line 3 / 8” - 5 / 8”
- Refrigerant R410A / 1.950g
- Outdoor Operation Temperature Range - Cooling/Heating -15~50/ - 15~24 °C
- V4MFI - 50 / V4MF0 - 50
- Cooling Capacity 48.000 Btu / h
- Heating Capacity 50.000 Btu / h
- Cooling Capacity Range (13.500 - 51.000) Btu / h
- Cooling Capacity Range 14.07 (3.96 - 14.95) kWatt
- Heating Capacity (8.700 - 58.000) Btu / h
- Heating Capacity 14.65(2.43-17.0) kWatt
-
Seasonal Efficiency(In accordance
to EN14825) Cooling - Pdesign 14.0 kW
- Energy Class A++
- SEER 6.1
-
Seasonal Efficiency(In accordance
to EN14825) Heating Middle Zone - Pdesign 11.1 kW
- Energy Class Α+
- SCOP 4.0
-
Seasonal Efficiency(In accordance
to EN14825) Heating Warm Zone - Pdesign 11.6 kW
- Energy Class A+++
- SCOP 5.1
- EER / COP 2.81 / 3.30
- Voltage / Frequency / Phase 380 / 50 / 3 V / Hz / Ph
- Current Input - Cooling 8.8 Α
- Current Input - Heating 7.0 Α
- Power Input - Cooling 5.000 W
- Power Input - Heating 4.440 W
- Air Flow Volume (High/Medium/Low) 2.150/1.850 /1.450 m3 / h
- Noise Level - Indoor unit (Low/Medium/High) 44 / 48 / 53 dB (A)
- Noise Level - Outdoor unit 64 dB (A)
- Sound Power Level - Indoor/Outdoor unit 63 / 72 dB (A)
- Power Supply Wire Outdoor / Fuses 5 × 2.5 / 3 × 25 No x mm2 / Α
- Signal Wires 3 × 2.5 (2 × 0.5 Shield) No x mm2
- Dimensions WxDxH - Indoor unit 600 × 455 × 1.934 mm
- Dimensions WxDxH - Outdoor unit 952 × 415 × 1.333 mm
- Net Weight - Indoor / Outdoor 61.6 / 108.1 kg
- Liquid line | Gas line 3 / 8” - 5 / 8”
- Refrigerant R410A / 4.000g
- Outdoor Operation Temperature Range - Cooling/Heating -15~50/ - 25~30 °C
- V4MFI - 66 / V4MF0 - 66
- Cooling Capacity 53.000 Btu / h
- Heating Capacity 60.000 Btu / h
- Cooling Capacity Range (14.000 - 55.000) Btu / h
- Cooling Capacity Range 15.53 (4.10 - 16.12) kWatt
- Heating Capacity (14.500-63.000)+12.000 Btu / h
- Heating Capacity 17.58(4.25-18.46)+3.517 kWatt
-
Seasonal Efficiency(In accordance
to EN14825) Cooling - Pdesign 15.6 kW
- Energy Class A++
- SEER 6.0
-
Seasonal Efficiency(In accordance
to EN14825) Heating Middle Zone - Pdesign 12.3 kW
- Energy Class Α+
- SCOP 4.0
-
Seasonal Efficiency(In accordance
to EN14825) Heating Warm Zone - Pdesign 12.6 kW
- Energy Class A+++
- SCOP 5.1
- EER / COP 2.63 / 2.93
- Voltage / Frequency / Phase 380 / 50 / 3 V / Hz / Ph
- Current Input - Cooling 9.4 Α
- Current Input - Heating 10.7 Α
- Power Input - Cooling 6.200 W
- Power Input - Heating 6.000 W
- Air Flow Volume (High/Medium/Low) 2.150/1.850/1.450 m3 / h
- Noise Level - Indoor unit (Low/Medium/High) 44 / 48 / 52 dB (A)
- Noise Level - Outdoor unit 66 dB (A)
- Sound Power Level - Indoor/Outdoor unit 67 / 74 dB (A)
- Power Supply Wire Outdoor / Fuses 5 × 2.5 / 3 × 25 No x mm2 / Α
- Signal Wires 5 × 2.5 (2 × 0.5 Shield) No x mm2
- Dimensions WxDxH - Indoor unit 600 × 455 × 1.934 mm
- Dimensions WxDxH - Outdoor unit 952 × 415 × 1.333 mm
- Net Weight - Indoor / Outdoor 65.0 / 112.8 kg
- Liquid line | Gas line 3 / 8” - 5 / 8”
- Refrigerant R410A / 4.300g
- Outdoor Operation Temperature Range - Cooling/Heating 18~43/ - 7~24 °C
More
Hervorragende Heizleistung unter -15°C
Hervorragende Heizleistung auch in den anspruchsvollsten Regionen mit niedrigen Temperaturen. Sorgen Sie dafür daß Sie die bevorzugten Temperaturbedingungen auch bei -15°C einstellen und genießen Sie ideale Bedingungen in Ihre Räumlichkeiten.
Zentrales Steuerungssystem (wahlfrei)
Das zentralisierte Multifunktionsgerät kann bis zu 64 Inneneinheiten mit einer maximalen Verbindungslänge von 1200 m kontrollieren.
Turbo Modus
Diese Funktion erhöht die Kühl- und Heizleistung für einen bestimmten Zeitraum und lässt den Raum schnell abkühlen oder schnell aufwärmen.
Sperren
Aktivieren Sie die Sperrfunktion, um zu verhindern, dass jemand die Einstellungen verändert oder dass Kinder mit dem Gerät spielen.
Intelligente Fernbedienung
Nutzen Sie die 4 Auswahlmöglichkeiten, um die Lüftergeschwindigkeit der Inneneinheit anzupassen und profitieren Sie vom Vorteil der Filterreinigungs Erinnerungsmodus, dem Lamellenpositionsspeicher, dem Temperaturkompensationssensor und der Einstellung für höhere / niedrigere Temperaturen, um die idealen Bedingungen in Ihre Räumlichkeiten zu erzielen.
Media Library for Floor Standing
User & Installation Manuals - Energy Labels - Pdesign Test Report - High Resolution Photos
All you need to know about
Register now using your e-mail and get all the latest news in the world of air conditioning and more …